D45AT6 — Three-phase autotransformer 230 → 400

Three-phase autotransformer intended for homes and residential installations with a 230 V three-phase supply that need to power equipment or a circuit designed for 400 V. It adapts voltage without providing galvanic isolation.

The IP65 version provides a higher level of protection against dust and water, making it more suitable where the residential installation requires a more protected enclosure. Final location must comply with the intended installation and service conditions. As an autotransformer, input and output are not electrically isolated; suitability for the equipment and the home's protection scheme must be checked. It is also designed for residential use with quiet operation and low energisation inrush current, reducing the risk of nuisance circuit-breaker tripping.

Technical data

Input voltage
230 V
Output voltage
400 V
Frequency
50/60 Hz
Thermal class
<63 kVA: F (140ºC) / Ta=40ºC - ≥63 kVA: H (165ºC) / Ta=40ºC
Degree of protection
IP-65
Cooling
AN
Protection against electric shock
Class I
Test voltage
4,5 KV
Vector group
YN0
Relevant parameters
Reversible: 230 / 400 V o 400 / 230 V

Application

230 V to 400 V adaptation in residential three-phase installations

Three-phase autotransformer intended for homes and residential installations with a 230 V three-phase supply that need to power equipment or a circuit designed for 400 V. It adapts voltage without providing galvanic isolation.

The IP65 version provides a higher level of protection against dust and water, making it more suitable where the residential installation requires a more protected enclosure. Final location must comply with the intended installation and service conditions. As an autotransformer, input and output are not electrically isolated; suitability for the equipment and the home's protection scheme must be checked. It is also designed for residential use with quiet operation and low energisation inrush current, reducing the risk of nuisance circuit-breaker tripping.

References and dimensions

ReferencePowerInput voltageOutput voltageA × B × CWeight
340D45AT64 kVA230 V400 V370 × 302 × 384 mm36 kg
350D45AT65 kVA230 V400 V500 × 372 × 584 mm46 kg
363D45AT63 kVA230 V400 V500 × 372 × 584 mm51 kg
380D45AT68 kVA230 V400 V500 × 372 × 584 mm60 kg
410D45AT610 kVA230 V400 V500 × 372 × 584 mm65 kg
413D45AT613 kVA230 V400 V500 × 372 × 584 mm71 kg
416D45AT616 kVA230 V400 V660 × 490 × 734 mm102 kg
420D45AT620 kVA230 V400 V660 × 490 × 734 mm110 kg
425D45AT625 kVA230 V400 V660 × 490 × 734 mm133 kg
431D45AT631.5 kVA230 V400 V660 × 490 × 734 mm150 kg
440D45AT640 kVA230 V400 V660 × 490 × 734 mm180 kg
450D45AT650 kVA230 V400 V660 × 490 × 734 mm202 kg

Dimension reference

Dimensions A, B, C, d and e in the table correspond to those shown in this image.

Dimension reference · D45AT6